New Items

IFM SA4100 Flow Sensor

Request Callback

₹ 33000 / Piece Get Latest Price

Product Brochure
Part NumberSA4100
ApplicationIndustrial
Flow Rate0-200 m/s
BrandIFM
OutputDigital-PNP/NPN & Analog 4-20mA
Maximum Pressure50 Bar
Supply Voltage18-30VDC
MaterialStainless Steel
Probe Length100mm
Process ConnectionClamp Adapter 8mm
Mediawater; glycol solutions; air; oils
Temp Monitoring-25 To 80 Deg C
ProtectionIP65 & IP67
IFM SA4100
SAEXXXXBFRKG/US-100
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Process connection clamp adapter Ø 8 mm
Application
Special feature Gold-plated contacts
Media water; glycol solutions; air; oils
Note on media
low-viscosity oils with viscosity: ≤ 40 mm²/s (40 °C)
high-viscosity oils with viscosity: > 40 mm²/s (40 °C)
Medium temperature[°C] -20...100
Pressure rating
50 bar 5 MPa
MAWP (for applications according to CRN)[bar] 50
Electrical data
Operating voltage[V] 18...30 DC
Current consumption[mA] < 100
Protection class III
Reverse polarity protection yes
Power-on delay time[s] 10
Measuring principle calorimetric
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Outputs
Total number of outputs 2
Output signal switching signal; analogue signal; frequency signal; IO-Link; (configurable)
Electrical design PNP/NPN
Number of digital outputs 2
Output function normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC[V] 2.5
Permanent current rating of switching output DC[mA] 250
Number of analogue outputs 1
Analogue current output[mA] 4...20; (scalable)
Max. load[Ω] 350
Short-circuit protection yes
Type of short-circuit protection pulsed
Overload protection yes
Frequency of the output[Hz] 0...1000
Measuring/setting range
Probe length L[mm] 100
Operating mode relative; abso

Balluff BIS00LH BIS M-400-045-001-07-S4 IO Link Reader

Request Callback

₹ 27500 / Piece Get Latest Price

Product Brochure
Usage/ApplicationNavigation
Frequency13.56 MHz
Type Of SystemHF (13.56MHz)
Tag TypeActive
BrandBalluff
Model Name/NumberBUS003F
Dia30mm
ProtectionIP67
Antenna TypeRound
Length83mm
Key featuresProduct groupHF (13.56 MHz)DimensionØ 30 x 83 mmInstallationmetal-free (clear zone)Antenna typeroundSupported data carrier typesDIN ISO 14443
DIN ISO 15693ConnectionConnector, M12x1-Male, 4-pinHousing materialBrass, Nickel-plated brass nuts, nickel-platedAmbient temperature-20...80 °CIP ratingIP67Approval/ConformityCE
UKCA
cULus
FCC
IC (Radio)
WEEE
MIC
KC
NBTC
IMDA
MCMC

IFM DN4012 Switch Mode Power Supply

Request Callback

₹ 20000 / Piece Get Latest Price

Product Brochure
Output Voltage24V DC
Output Current5A
Output Power120W
Mounting TypeDIN Rail
Input VoltageUniversal AC (90-264V)
Number of OutputsSingle
ProtectionsShort Circuit Protection, Overload Protection, Over Temperature Protection, Over Voltage Protection
FeaturesAdjustable Output Voltage

Minimum order quantity: 1 Piece

Application
Design housing for DIN rail mounting
Electrical data
Frequency AC[Hz] 47...64
Operating voltage tolerance[%] 10
Operating voltage tolerance 2[%] 10
Operating voltage[V] automatic range selection
Nominal voltage AC[V] < 230
Input voltage range AC[V] 100...120 / 200...240; (automatic range selection)
Output voltage DC[V] 24...28
Protection class I; (IEC 61140)
Overvoltage protection yes; (< 39 DC)
Output voltage[V] adjustable; output voltage to SELV, PELV
Max. output current at min. output voltage[A] 5
Max. output current at max. output voltage[A] 4.3
Max. output current peak at min. output voltage[A] 6
Max. output current peak at max. output voltage[A] 5.1
Output power (permanent)[W] 120
Output power (peak)[W] 144
Note on output power (peak)[W]
≤ 45 °C permitted continuously; > 45 °C < 1 minute every 10 minutes
Power factor (nominal voltage 120 V AC / 60 Hz) 0.56
Power factor (nominal voltage 230 V AC / 50 Hz) 0.47
Power reserve[%] 20
Number of output circuits 1
Max. residual ripple[mV] 50
Switch-on peak current (nominal voltage 120 V AC / 60 Hz)[A] 3
Switch-on peak current (nominal voltage 230 V AC / 50 Hz)[A] 3
Inrush current limitation yes
Efficiency (nominal voltage 120 V AC / 60 Hz)[%] 89.4
Efficiency (nominal voltage 230 V AC / 50 Hz)[%] 90.2
External input protection ≤ B-10 A / ≤ C-6 A
Derating[W/K] 3 (60...70 °C)
Mains buffering time (nominal voltage 120 V AC / 60 Hz)[ms] 80
Mains buffering time (nominal voltage 230 V AC / 50 Hz)[ms] 78
Input current (nominal voltage 120 V AC / 60 Hz)[A] 2.05
Input current (nominal voltage 230 V AC / 50 Hz)[A] 1.23
Power loss (nominal voltage 120 V AC / 60 Hz)[W] 14.5
Power loss (nominal voltage 230 V AC / 50 Hz)[W] 13.2
Back feeding protection[V] 35
Outputs
X

Contact Us

Akshay Khanna (Partner)
Accrete Automation India Private Limited
B-13, Lehri Colony, East Arjun Nagar
Shahdara, New Delhi - 110032, Delhi, India

Get Directions
Send Email
Share: